3. INITIAL DEVICE SETUP

3.1 MINER IDENTIFICATION ON THE NETWORK

You will need to determine the IP address of the miner received from the router/modem.

  • Run the utility WhatsMinerTool
  • Press the button [ IP Monitor ]
  • In the opened “Detect and Bind IP” window, click the button [ Start ]

  • Press and hold the IP found button on the device panel until the green and red LEDs flash together several times.

At the same time, a line with our miner should appear in the Detect and Bind IP window.

  • Pay attention to the Source IP column (for example, 192.168.88.96) - this address must be remembered.

  • Close this window and confirm closing (press [Ok] in the pop-up question).

Now you need to add the network scan range of the utility WhatsMinerTool

  • Press the button [ Miner IP ]

If there are already any entries in this window, you can delete them, modify them, or simply add new ones.

LET’S ADD A NEW ONE

  • In the Start IP field enter the previously obtained IP address, changing the last digit to “1” (192.168.88.1).
  • In the End IP field enter the received IP address, changing the last digit to 255 (192.168.88.255)
  • Press the button [ Add ]
  • The entered range will be displayed in the list .

  • Close the window or click [Ok] at the bottom of the window.

Now you can run a network scan.

  • In the main utility window, click [ Start ]

In this case, the button will change its name to “Monitoring”, scanning will start and after a while the found devices will be displayed in the list.

3.2 DATA DISPLAY SETUP

  • Press the button [ Settings ]
  • Under List Column Display Mode, select Complete Mode
  • Press [ Save ] 

 

 

3.3 POOL AND WORKER SETUP

This setting can be done both using the WhatsMinerTool utility and through the miner’s web interface.

3.3.1 CONFIGURATION OF POOLS THROUGH THE UTILITY WHATSMINERTOOL

  • In the main window of the utility, check the list of miners that need to change the pool and worker.
  • Press the button [ Pools ] . An area with the corresponding form will open.
  • Fill in the fields Pool, Worker, Pwd (password) by the required data.
  • If you have only one or two pools - just uncheck the unnecessary lines in the form.

  • Press the button [ Start Update ] , pool settings will be applied.
  • To hide the pools form - press the [Pools] button again.

3.3.2 CONFIGURATION OF POOLS THROUGH THE WEB INTERFACE OF THE MINER

  • Open the IP address of the miner in the browser (for example, https://192.168.88.96) and enter the login / password set on the device (by default - admin / admin)
  • Go to section  Configuration > Miner Configuration, tab Pool
  • To set the pool in the Pool 1 drop down menu select custom. An input field will appear instead of the drop down menu.
  • Fill in the field that appears, as well as Pool 1 worker and Pool Password

  • If necessary, set the Pool 2 and Pool 3
  • Press [Save & Apply], to save settings.

After changing pools, you need to restart the miner.