All documents
Home Documentation Connecting an additional power supply unit 2. The connection procedure of the additional power supply unit
Leave your email so you don't miss out!
By subscribing, you agree to our
Privacy Policy!

2. THE CONNECTION PROCEDURE OF THE ADDITIONAL POWER SUPPLY UNIT

  • Disconnect the fan terminal
  • Loosen the screws holding the module with the control board
  • Disconnect the power supply unit cable

  • Remove the control board module, if necessary, disconnect it completely by disconnecting the cable
  • Unscrew the screw of the minus bar and replace it with a similar one, taking into account the thickness of the additional terminal
  • Loosen the screws of the plus bar and remove it

  • Modify the bar by removing the shaded area , or prepare a similar one from the copper plate

  • Install the modified busbar and screw it on . The contacts of the first board must remain “free”

  • Connect the plus terminal to the plus terminal of the board, the minus terminal to the plus bus

Make sure there are no accidental short circuits and contact between the plus terminal of the additional power supply unit and the miner's plus plate .

  • Connect the power wires to the additional power supply unit: plus terminal to the plus contact of the PSU, minus terminal to the minus contact.

Before turning on the miner, you must turn on the additional power supply unit, then the miner.

x