2. THE CONNECTION PROCEDURE OF THE ADDITIONAL POWER SUPPLY UNIT

  • Disconnect the fan terminal ①
  • Loosen the screws ② holding the module with the control board
  • Disconnect the power supply unit cable ③

  • Remove the control board module, if necessary, disconnect it completely by disconnecting the cable ①
  • Unscrew the screw ② of the minus bar and replace it with a similar one, taking into account the thickness of the additional terminal
  • Loosen the screws ③ of the plus bar and remove it

  • Modify the bar by removing the shaded area ①, or prepare a similar one from the copper plate

  • Install the modified busbar and screw it on ①. The contacts of the first board ② must remain “free”

  • Connect the plus terminal to the plus terminal ① of the board, the minus terminal to the plus bus ②

Make sure there are no accidental short circuits and contact between the plus terminal of the additional power supply unit and the miner's plus plate ③.

  • Connect the power wires to the additional power supply unit: plus terminal ① to the plus contact of the PSU, minus terminal ② to the minus contact.

Before turning on the miner, you must turn on the additional power supply unit, then the miner.